Partial Discharge Shielded RoomPartial Discharge Shielded Room
A partial-discharge test shielded room is primarily used to prevent external electromagnetic interference from affecting partial-discharge tests. The shielded room must have a good grounding and isolation system to effectively prevent interference from electrostatic fields, magnetic fields and high-frequency electromagnetic waves.
Product overview
A partial-discharge test shielded room is primarily used to prevent external electromagnetic interference from affecting partial-discharge tests. The shielded room must have a good grounding and isolation system to effectively prevent interference from electrostatic fields, magnetic fields and high-frequency electromagnetic waves.
Product Specifications
Specification Image 1

Technical data
- Construction type
- Modular assembly / welded
- Magnetic-field shielding performance
- ≥60dB at 10kHz~100kHz
- Electric-field shielding performance
- ≥60dB at 100kHz~1GHz
- Partial-discharge background noise
- ≤1pC under no-load test-circuit conditions
- Test observation method
- Observation window / monitoring system
- Main door type
- Motorized / manual airtight shielded sliding door; manual double-leaf hinged door
- Small door type
- Manual single-leaf locking shielded door
- Six-sided shielding modules
- Galvanized / cold-rolled steel sheet
- Control-room partition
- Framing + double-sided integrated wall panels
- Wall finish
- Integrated wall panels + stainless-steel trim
- Floor finish
- Self-leveling epoxy floor / anti-rust paint
Need help confirming your product configuration?